S4-Medcare-Nashik-India

 

S4 Medcare- Dealers Cpap Machince - Rentals- Nashik - India

 

S4 Medcare Nashik India - Dealers in Auto Cpap Machine  Medical Spirometer Medical Spirometer - Spirodoc Hand Held Spirometer Spirodoc Hand Held Spirometer

By keeping track of market developments, we are involved in offering a high quality  Spirodoc Hand Held Spirometer. In conformance with the international quality standards, the offered spirometer is manufactured at our vendor's end using optimum quality components and innovative technology. Our offered spirometer is available in various models and configurations that are easy to use for family doctors screening or pharmacy quick tests. 

Spirodoc Hand Held SpirometerFeatures:

  • Excellent functionality
  • Accurate result
  • Reliability

Spiro meter technical specifications:

  • Flow sensor: bi-directional digital turbine
  • Flow range ±16L/s
  • Volume accuracy: ±3% o 50mL, whichever is greater
  • Flow accuracy: ±5% o 200mL/s, whichever is greater
  • Dynamic resistance at 12L/s: <0.5cmH2O/L/s
  • Temperature sensor: semiconductor (0-45°C)

Spiro meter measured parameters:

  • FVC, FEV1, FEV1/FVC%, FEV3, FEV3/FVC%, FEV6, FEV1/FEV6%, PEF, FEF25%, FEF50%, FEF75%, FEF25%-75%, FET, Estimated Lung Age, Extr. Vol., FIVC, FIV1, FIV1/FIVC%, PIF, VC, IVC, IC, ERV, FEV1/VC%, VT, VE, Rf, ti, te, ti/t-tot, VT/ti, MVV measured, MVV calculated

Central unit technical specifications:

  • Display: LCD Backlit Touch screen Display
  • Resolution: 128x64 pixels
  • Power supply: Lithium ion 3.7V, 1100mA rechargeable battery
  • Data transmission: USB 2.0 On-The-Go and Bluetooth® 2.1
  • Accelerometer: Triaxial ± 2g, 400Hz sampling
  • Dimensions and weight: central unit 101x48x16mm, 99g
  • removable turbine head: 46x47x24mm, 17g
  • Battery charger (optional): 100VAC - 240VAC, 50Hz-60Hz
  • output 5VDC, 500mA, micro USB type B

Pulse-oximeter technical specifications

  • SpO2 range: 0-99%
  • SpO2 accuracy: ±2% (70-99% SpO2)
  • Heart rate range: 30-254BPM
  • Heart rate accuracy: ±2BPM or 2%, whichever is greater
  • Pulse-oximeter measured parameters (standard)
  • SpO2 [Baseline, Min, Max, Mean], Pulse rate [Baseline, Min, Max, Mean], T90% [SpO2<90%], T89% [SpO2<89%], T88% [SpO2<88%], T5% [ΔSpO2>5%], ΔIndex [12s], SpO2 Events, Pulse rate events [Bradycardia, Tachycardia], Step counter, Movement [VMU], Recording time, Analysis time
  • Sleep analysis (specific parameters)
  • Body position, SpO2 Events, Desaturation index (ODI), Desaturation [Mean Value, Mean duration, Longest duration, Nadir Peak], ΔSpO2 [Min Drop, Max Drop], Total Pulse Variations, Pulse Rate Index, NOD89% [SpO2<89%; >5min], NOD4% [SpO2 Basale-4%; >5min], NOD90% [SpO2<90%; Nadir<86%; >5min]
  • 6MWT (6 Minute Walk Test specific parameters)
  • O2-Gap, Estimated distance, Distance walked, Predicted distance [Min, Standard], TΔ2% [SpO2≥2%], TΔ4% [ΔSpO2≥4%], Time [Rest, Walking, Recovery], Desaturation Area/Distance Optional data entry: Borg Dyspnea [Baseline, End, Change], Borg Fatigue [Baseline, End, Change], Arterial blood pressure [Systolic, Diastolic], Oxygen administered

 